TM 1-1520-238-T-5
Change 7
8117
849.
CPG SDD PANEL TGT DIGITAL READOUT DOES NOT INDICATE AMBIENT
849
TEMPERATURE 5
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer (2)
References:
TM 1-1520-238-23
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Check pilot TGT indicator.
Are digital readouts within 5 temperature?
YES
Go to step 2.
NO
Go to paragraph 832 to
troubleshoot pilot TGT indicator.
2. With pilot and CPG ENG INST circuit breakers
(CB 17 and CB 31) closed and ambient
temperature greater than 0 C, check for 0 to
5 VDC at:
P7528 and P7529.
Is voltage present?
YES
Replace CPG SDD panel
(TM 1-1520-238-23).
NO
Go to step 3.
3. Check for open between:
P7528 and P681,
P7529 and P682.
Does open exist?
YES
Repair open wire.
Go to paragraph 810.
NO
Replace pilot TGT indicator
(TM 1-1520-238-23).
END OF TASK