TM 1-1520-238-T-5
8112
844.
CPG ENGRTR RPM% DOES NOT INDICATE FULL SCALE OR VERTICAL SCALE
844
INDICATORS HAVE EVERY OTHER LAMP NOT LIGHTED (HELICOPTERS WITH CPG
DIM/TEST PANEL INSTALLED)
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer (2)
References:
TM 1-1520-238-23
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. On CPG dim/test panel, hold
DGT OFF/NORM/TST switch to TST. Check for
short between P7317 and ground.
Does short exist?
YES
Go to step 2.
NO
Repair open wire between
P7317 and P73SP1.
Go to paragraph 810.
2. Check for 2 to 5 VDC at P737 and P738.
Is voltage present?
YES
Go to step 3.
NO
Go to step 6.
3. Check for:
8 VDC at P7313,
8 VDC at P7314.
Are voltages present?
YES
Go to step 4.
NO
Go to step 5.
4. Check for open between:
P739 and GS245C,
P7310 and GS245D,
P7311 and GS255A.
Does open exist?
YES
Repair open wire.
Go to paragraph 810.
NO
Replace CPG ENGRTR
RPM% indicator
(TM 1-1520-238-23).
5. Check for open between:
P7313 and P40010,
P7314 and P4002.
Does open exist?
YES
Repair open wire.
Go to paragraph 810.
NO
Replace SDC
(TM 1-1520-238-23).
6. Check for open between:
P737 and P10932,
P738 and P10935.
Does open exist?
YES
Repair open wire.
Go to paragraph 810.
NO
Replace CPG ENG INST
dimmer power supply.
(TM 1-1520-238-23).
END OF TASK