(m) Overcurrent protection is available when only one T/R is operating (bus tie relay energized). When
the bus tie relay is energized, 28 VDC is routed through the overcurrent (OC) sensing coil. If current flow through
the bus tie relay exceeds 300 30 amps, the overcurrent relay will energize. When the OC relay energizes, the
coil to the bus tie relay is opened, deenergizing the bus tie relay. The shorted bus will be deenergized when the
overcurrent relay is energized.