TM 1-1520-238-T-6
9298
9103. PILOT UTILITY AND SECONDARY LIGHTS MAINTENANCE
9103
OPERATIONAL CHECK (cont)
1. Perform the maintenance operational check as follows:
Task
Result
a. On pilot center circuit breaker panel
(fig. 9139), check that LT UTIL SEC circuit
breaker (CB23) is closed.
If LT UTIL SEC circuit breaker (CB23) does not stay
closed, go to paragraph 9105.
M69-153
LT UTIL SEC
Figure 9139.
Pilot Center Circuit Breaker Panel
b. On pilot EXT LT/INTR LT panel (fig. 9140),
set FLOOD switch (S1) to DIM, and then to
BRT. Check that all glareshield secondary
lights light in both positions.
If all secondary lights light in one position and not the
other, replace pilot EXT LT/INTR LT panel
(TM 1-1520-238-23).
If LT UTIL SEC circuit breaker (CB23) does not stay
closed, go to paragraph 9105.
If one or more lights do not light in both positions, go
to paragraph 9106.
M69-154
FLOOD SWITCH
Figure 9140.
Pilot EXT LT/INTR LT Panel
c. Remove pilot utility light (fig. 9141) from
mounting bracket.
d. While holding pilot utility light, turn rheostat
to BRT. Check that utility light is lighted.
If utility light does not light, go to paragraph 9107.