TM 1-1520-238-T-6
9296
9102. MAINTENANCE LIGHT DOES NOT LIGHT IN RIGHT FORWARD AVIONICS BAY
9102
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
R295 and B60R doors
opened
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
Check for open between J112B and CB82.
Does open exist?
YES
Repair open between J112B
and CB82.
Go to paragraph 998.
NO
Repair open between J112A
and ground.
Go to paragraph 998.
END OF TASK