TM 1-1520-238-T-6
9386
9150.
CIRCUIT PROTECTION SYSTEM (AC ESSENTIAL BUS 1 PILOT STATION)
9150
MAINTENANCE OPERATIONAL CHECK (cont)
Task
Result
x. Check for 115 VAC at P1-45.
If 115 VAC is not present, go to paragraph 9162.
y. Check for 115 VAC at P1-44.
If 115 VAC is not present, go to paragraph 9163.
z. Check for 115 VAC at P1-24.
If 115 VAC is not present, go to paragraph 9164.
aa. Check for 115 VAC at P1-26.
If 115 VAC is not present, go to paragraph 9160.
ab. Check for 115 VAC at P1-54.
If 115 VAC is not present, go to paragraph 9165.
ac. Check for 115 VAC at P1-30.
If 115 VAC is not present, go to paragraph 9157.
ad. Check for 115 VAC at P1-28.
If 115 VAC is not present, go to paragraph 9158.
ae. Check for 115 VAC at P1-22.
If 115 VAC is not present, go to paragraph 9168.
af. Check for 115 VAC at P1-36.
If 115 VAC is not present, go to paragraph 9169.
ag. Check for 115 VAC at P1-37.
If 115 VAC is not present, go to paragraph 9170.
ah. On pilot ELEC PWR panel (fig. 9157), set
BATT/EXT PWR switch to OFF.
ai. On electrical power distribution box, attach
P1 and detach P3.
aj. On pilot aft circuit breaker panel (fig. 9158),
check that POWER XFMR RECT 1 circuit
breaker (CB1) is closed.
If POWER XFMR RECT 1 circuit breaker (CB1) does
not stay closed, go to paragraph 9167.
ak. On electrical power distribution box, attach
P3.
2. Perform EXTERNAL POWER POWER DOWN (para 946).
END OF TASK