TM 1-1520-238-T-6
9383
9150. CIRCUIT PROTECTION SYSTEM (AC ESSENTIAL BUS 1 PILOT STATION)
9150
MAINTENANCE OPERATIONAL CHECK (cont)
Task
Result
g. On pilot forward circuit breaker panel
(fig. 9158), close the following circuit
breakers:
MISSION PNVS AC (CB81),
MISSION IHADSS (CB41),
MISSION RDR JAM AC (CB74),
MISSION SYM GEN (CB45),
MISSION EL AC (CB92),
MISSION FC AC (CB51),
NAV HARS AC (CB42),
NAV HSI (CB43),
NAV AIR DATA AC (CB84).
If MISSION PNVS AC circuit breaker (CB81) does not
stay closed, go to paragraph 9153.
If MISSION IHADSS circuit breaker (CB41) does not
stay closed, go to paragraph 9154.
If MISSION RDR JAM AC circuit breaker (CB74)
does not stay closed, go to paragraph 9155.
If MISSION SYM GEN circuit breaker (CB45) does
not stay closed, go to paragraph 9156.
If MISSION EL AC circuit breaker (CB92) does not
stay closed, go to paragraph 9157.
If MISSION FC AC circuit breaker (CB51) does not
stay closed, go to paragraph 9158.
If NAV HARS AC circuit breaker (CB42) does not stay
closed, go to paragraph 9159.
If NAV HSI circuit breaker (CB43) does not stay
closed, go to paragraph 9160.
If NAV AIR DATA AC circuit breaker (CB84) does not
stay closed, go to paragraph 9161.
h. On pilot center circuit breaker panel, close
the following circuit breakers:
LT PRI (CB39),
LT ANTI COL (CB40),
LT FORM (CB90),
ASE AC (CB18).
If LT PRI circuit breaker (CB39) does not stay closed,
go to paragraph 9162.
If LT ANTI COL circuit breaker (CB40) does not stay
closed, go to paragraph 9163.
If LT FORM circuit breaker (CB90) does not stay
closed, go to paragraph 9164.
If ASE AC circuit breaker (CB18) does not stay
closed, go to paragraph 9165.
i. On pilot aft circuit breaker panel, close the
following circuit breakers:
ECS L NOSE GRBX HTR (CB38),
POWER XFMR RECT 1 (CB1),
POWER ENG 1 (CB62),
STAB AUTO AC (CB2),
STAB MAN AC (CB7),
ECS R NOSE GRBX HTR (CB211).
If ECS L NOSE GRBX HTR circuit breaker (CB38)
does not stay closed, go to paragraph 9166.
If POWER XFMR RECT 1 circuit breaker (CB1) does
not stay closed, go to paragraph 9167.
If POWER ENG 1 circuit breaker (CB62) does not
stay closed, go to paragraph 9168.
If STAB AUTO AC circuit breaker (CB2) does not
stay closed, go to paragraph 9169.