TM 1-1520-238-T-6
9403
9162. LT PRI CIRCUIT BREAKER (CB39) DOES NOT STAY CLOSED OR 115 VAC IS
9162
NOT PRESENT AT P1-45
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. On pilot ELEC PWR panel, set BATT/EXT PWR
switch to EXT PWR.
Does LT PRI circuit breaker (CB39) stay
closed?
YES
Go to step 4.
NO
Go to step 2.
2. Open CB39. Set BATT/EXT PWR switch to OFF.
Check for short between P1-45 and ground.
Does short exist?
YES
Go to step 3.
NO
Go to paragraph 9113 to
troubleshoot pilot edge-lights.
3. Detach wire at CB39-2. Check for short between
P1-45 and ground.
Does short exist?
YES
Repair shorted wire between
CB39-2 and P1-45.
Go to paragraph 9150.
NO
Replace LT PRI circuit breaker
(CB39) (TM 1-1520-238-23).
4. Set BATT/EXT PWR switch to OFF. Check for
open between:
CB39-1 and CB45-1,
CB39-2 and P1-45.
Does open exist?
YES
Repair open wire.
Go to paragraph 9150.
NO
Replace LT PRI circuit breaker
(CB39) (TM 1-1520-238-23).
END OF TASK