TM 1-1520-238-T-6
9404
9163. LT ANTI COL CIRCUIT BREAKER (CB40) DOES NOT STAY CLOSED OR 115 VAC
9163
IS NOT PRESENT AT P1-44
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. On pilot ELEC PWR panel, set BATT/EXT PWR
switch to EXT PWR.
Does LT ANTI COL circuit breaker (CB40)
stay closed?
YES
Go to step 4.
NO
Go to step 2.
2. Open CB40. Set BATT/EXT PWR switch to OFF.
Check for short between P1-44 and ground.
Does short exist?
YES
Go to step 3.
NO
Go to paragraph 970 to
troubleshoot collision lights.
3. Detach wire at CB40-2. Check for short between
P1-44 and ground.
Does short exist?
YES
Repair shorted wire between
CB40-2 and P1-44.
Go to paragraph 9150.
NO
Replace LT ANTI COL circuit
breaker (CB40)
(TM 1-1520-238-23).
4. Set BATT/EXT PWR switch to OFF. Check for
open between:
CB40-1 and CB39-1,
CB40-2 and P1-44.
Does open exist?
YES
Repair open wire.
Go to paragraph 9150.
NO
Replace LT ANTI COL circuit
breaker (CB40)
(TM 1-1520-238-23).
END OF TASK