TM 1-1520-238-T-6
9416
9172. CIRCUIT PROTECTION SYSTEM (AC ESSENTIAL BUS 1 CPG STATION)
9172
MAINTENANCE OPERATIONAL CHECK (cont)
Task
Result
k. On CPG circuit breaker panel 1
(fig. 9161), check that
AWS AWS AC (CB11),
MSL R LCHR AC (CB18),
MSL R LCHR AC (CB21),
MSL L LCHR AC (CB24),
MSL L LCHR AC (CB26),
FC FCC AC (CB16), and ATTD IND (CB20)
circuit breakers are closed.
If AWS AWS AC circuit breaker (CB11) does not stay
closed, go to paragraph 9176.
If MSL R LCHR AC circuit breaker (CB18) does not
stay closed, go to paragraph 9177.
If MSL R LCHR AC circuit breaker (CB21) does not
stay closed, go to paragraph 9178.
If MSL L LCHR AC circuit breaker (CB24) does not
stay closed, go to paragraph 9179.
If MSL L LCHR AC circuit breaker (CB26) does not
stay closed, go to paragraph 9180.
If FC FCC AC circuit breaker (CB16) does not stay
closed, go to paragraph 9181.
If ATTD IND circuit breaker (CB20) does not stay
closed, go to paragraph 9182.
l. On pilot ELEC PWR panel (fig. 9162), set
BATT/EXT PWR switch to OFF.
m. On CPG circuit breaker panel 1, detach
P766, P767, and P769.
n. On pilot ELEC PWR panel, place BATT/EXT
PWR switch to EXT PWR.
o. Check for 115 VAC at P769-L.
If 115 VAC is not present, go to paragraph 9175.
p. (AAK) Check for 115 VAC at P767-30 and
P767-31.
(ABQ) Check for 115 VAC at P767-31.
If 115 VAC is not present, go to paragraph 9183.
q. On pilot ELEC PWR panel, place BATT/EXT
PWR switch to OFF.
r. Check for continuity between (A77):
J4-L, J2-12, and J2-19.
If continuity does not exist, go to paragraph 9176.
s. Check for continuity between (A77):
J2-31 and J2-5.
If continuity does not exist, go to paragraph 9177.
t. Check for continuity between (A77):
J2-31 and J2-4.
If continuity does not exist, go to paragraph 9178.
u. Check for continuity between (A77):
J2-31 and J2-3.
If continuity does not exist, go to paragraph 9179.
v. Check for continuity between (A77):
J2-31 and J2-2.
If continuity does not exist, go to paragraph 9180.