TM 1-1520-238-T-6
9417
9172. CIRCUIT PROTECTION SYSTEM (AC ESSENTIAL BUS 1 CPG STATION)
9172
MAINTENANCE OPERATIONAL CHECK (cont)
Task
Result
w. (AAK) Check for continuity between
(A77)J2-30 and (A97)J2-35.
If continuity does not exist, go to paragraph 9181.
x. (ABQ) Check for continuity between
(A77):J4-L and J2-35.
If continuity does not exist, go to paragraph 9184.
y. (AAK) Check for continuity between
(A77):J2-30 and J1-6.
If continuity does not exist, go to paragraph 9182.
z. (ABQ) Check for continuity between
(A77):J4-L and J1-6.
If continuity does not exist, go to paragraph 9185.
aa. On CPG circuit breaker panel 1 (fig. 9161),
reconnect P766, P767, and P769.
ab. On CPG circuit breaker panel 2, check that
LASER (CB4), TADS AC (CB3) and
IHADSS (CB1) circuit breakers are closed.
ac. On pilot ELEC PWR panel (fig. 9162),
place BATT/EXT PWR switch to EXT PWR.
ad. Check that circuit breakers closed in step
aa. remain closed.
If LASER circuit breaker (CB4 does not stay closed,
go to paragraph 9186.
If TADS AC circuit breaker (CB3 does not stay
closed, go to paragraph 9187.
If IHADSS circuit breaker (CB1) does not stay closed,
go to paragraph 9188.
ae. On pilot ELEC PWR panel, place BATT/EXT
PWR switch to OFF.
af. On CPG circuit breaker panel 2 (fig. 9163),
detach P761 and P1.
M69-207
TADS AC
LASER
IHADSS
Figure 9163.
CPG Circuit Breaker Panel 2