TM 1-1520-238-T-6
9483
9219. CPG CBR BLWR CIRCUIT BREAKER (CB5) DOES NOT STAY CLOSED
9219
OR 28 VDC IS NOT PRESENT BETWEEN P997-A AND P997-B
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 3-4240-312-12&P
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. On CPG circuit breaker panel 2, close CBR
BLWR circuit breaker (CB5).
Does CBR BLWR circuit breaker (CB5) stay
closed?
YES
Go to step 4.
NO
Go to step 2.
2. Detach P997 and check for short between
P997-A and ground.
Does short exist?
YES
Go to step 3.
NO
Refer to TM 3-4240-312-12&P
to troubleshoot CBR blower
system.
3. Check for short between P1-K and ground.
Does short exist?
YES
Repair shorted wire between
J764-K and P997-A.
Go to paragraph 9215.
NO
Repair shorted wire between
P1-K and CB5-2.
Go to paragraph 9215.
4. Check for 28 VDC at P997-A.
Is voltage present?
YES
Go to step 6.
NO
Go to step 5.
5. Check for 28 VDC at (A402)J32-K.
Is voltage present?
YES
Repair open wire between
P461-K and P997-A.
Go to paragraph 9215.
NO
Go to paragraph 923 to
troubleshoot dc electrical power
generation.
6. Check for open between P997-B and ground.
Does open exist?
YES
Repair open wire between
P997-B and ground.
Go to paragraph 9215.
NO
Refer to TM 3-4240-312-12&P
to troubleshoot CBR blower
system.
END OF TASK