9220. CIRCUIT PROTECTION SYSTEM (DC ESSENTIAL BUS 2 PILOT STATION)
9220
MAINTENANCE OPERATIONAL CHECK (cont)
Task
Result
h. Check that circuit breakers in step f. remain
closed.
If MISSION ARM CONTR cicuit breaker (CB46) does
not stay closed, go to paragraph 9223.
If IR JAM XMTR cicuit breaker (CB66) does not stay
closed, go to paragraph 9224.
If MISSION PEN AIDS CONTR cicuit breaker (CB49)
does not stay closed, go to paragraph 9225.
If MISSION JETT cicuit breaker (CB89) does not stay
closed, go to paragraph 9226.
If NAV VDU cicuit breaker (CB91) does not stay
closed, go to paragraph 9227.
If FUEL TRANS cicuit breaker (CB56) does not stay
closed, go to paragraph 9228.
If FUEL BST cicuit breaker (CB57) does not stay
closed, go to paragraph 9229.
If TWHL LOCK cicuit breaker (CB59) does not stay
closed, go to paragraph 9230.
If LT NAV cicuit breaker (CB73) does not stay closed,
go to paragraph 9231.
If VIB MON cicuit breaker (CB79) does not stay
closed, go to paragraph 9232.
If LSR DET cicuit breaker (CB96) does not stay
closed, go to paragraph 9232.1.
i. On pilot ELEC PWR panel (fig. 9179), set
BATT/EXT PWR switch to OFF and detach
P1 and P2.
j. On pilot ELEC PWR panel, set BATT/EXT
PWR switch to EXT PWR.
k. Check for 28 VDC at P2-E.
If 28 VDC is not present, go to paragraph 9223.
l. Check for 28 VDC at P2-h.
If 28 VDC is not present, go to paragraph 9224.
m. Check for 28 VDC at P2-D.
If 28 VDC is not present, go to paragraph 9228.
n. Check for 28 VDC at P1-49.
If 28 VDC is not present, go to paragraph 9225.
o. Check for 28 VDC at P1-18.
If 28 VDC is not present, go to paragraph 9226.
p. Check for 28 VDC at P1-41 and P1-42.
If 28 VDC is not present, go to paragraph 9227.