TM 1-1520-238-T-6
9537
9257. MUX R PYL INBD CIRCUIT BREAKER (CB5) DOES NOT STAY CLOSED
9257
OR CONTINUITY DOES NOT EXIST BETWEEN (A77): J4-A AND J2-8
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
TM 9-1230-476-20-2
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. On pilot ELEC PWR panel, set BATT/EXT PWR
switch to EXT PWR.
Does MUX R PYL INBD circuit breaker (CB5)
stay closed?
YES
Go to step 4.
NO
Go to step 2.
2. Set BATT/EXT PWR switch to OFF. Check for
short between (A77)J2-8 and ground.
Does short exist?
YES
Go to step 3.
NO
Refer to TM 9-1230-476-20-2 to
troubleshoot multiplex
subsystem.
3. Detach wire at CB5-2. Check for short between
(A77)J2-8 and ground.
Does short exist?
YES
Repair shorted wire between
CB5-2 and (A77)J2-8.
Go to paragraph 9249.
NO
Replace MUX R PYL INBD
circuit breaker (CB5)
(TM 1-1520-238-23).
4. Open CB5. Set BATT/EXT PWR switch to OFF.
Check for open between:
CB5-1 and CB1-1,
CB5-2 and (A77)J2-8.
Does open exist?
YES
Repair open wire
Go to paragraph 9249.
NO
Replace MUX R PYL INBD
circuit breaker (CB5)
(TM 1-1520-238-23).
END OF TASK