9259. MUX FAB R CIRCUIT BREAKER (CB9) DOES NOT STAY CLOSED
9259
OR CONTINUITY DOES NOT EXIST BETWEEN (A77): J4-A AND J2-13
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
TM 9-1230-476-20-2
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. On pilot ELEC PWR panel, set BATT/EXT PWR
switch to EXT PWR.
Does MUX FAB R circuit breaker (CB9) stay
closed?
YES
Go to step 4.
NO
Go to step 2.
2. Set BATT/EXT PWR switch to OFF. Check for
short between (A77)J2-13 and ground.
Does short exist?
YES
Go to step 3.
NO
Refer to TM 9-1230-476-20-2 to
troubleshoot multiplex system.
3. Detach wire at CB9-2. Check for short between
(A77)J2-13 and ground.
Does short exist?
YES
Repair shorted wire between
CB9-2 and (A77)J2-13.
Go to paragraph 9249.
NO
Replace MUX FAB R circuit
breaker (CB9)
(TM 1-1520-238-23).
4. Open CB9. Set BATT/EXT PWR switch to OFF.
Check for open between CB10-1 and
(A77)J2-13.
Does open exist?
YES
Go to step 5.
NO
Replace MUX FAB R circuit
breaker (CB9)
(TM 1-1520-238-23).
5. Check for open between CB9-2 and (A77)J2-13.
Does open exist?
YES
Repair open wire.
Go to paragraph 9249.
NO
Replace bus bar between CB9
and CB10, and check for foreign
material (TM 1-1520-238-23).
END OF TASK