TM 1-1520-238-T-6
9601
9306. EMERG BATT ICS CIRCUIT BREAKER (CB13) DOES NOT STAY CLOSED
9306
OR CONTINUITY DOES NOT EXIST BETWEEN (A77): J4-C AND J1-5
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
CPG circuit breaker
panel 1 removed
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Close CB13. Check for short between (A77)J1-5
and ground.
Does short exist?
YES
Go to step 2.
NO
Go to step 3.
2. Detach wire at CB13-2. Check for short between
(A77)J1-5 and ground.
Does short exist?
YES
Repair shorted wire between
CB13-2 and (A77)J1-5.
Go to paragraph 9304.
NO
Replace EMERG BATT ICS
circuit breaker (CB13)
(TM 1-1520-238-23).
3. Check for open between CB13-2 and (A77)J1-5.
Does open exist?
YES
Repair open wire.
Go to paragraph 9304.
NO
Replace EMERG BATT ICS
circuit breaker (CB13)
(TM 1-1520-238-23).
END OF TASK