TM 1-1520-238-T-6
9606
9311.
CONTINUITY DOES NOT EXIST BETWEEN (A77)J4-C AND CB29-1 OR 28 VDC
9311
IS NOT PRESENT AT P769-C
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Electrical power
distribution box cover
removed
Paragraph 9304
All dc emergency circuit
breakers open
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. On pilot ELEC PWR panel, set BATT/EXT PWR
switch to EXT PWR. Check for 28 VDC at
(A402)J32-G.
Does short exist?
YES
Go to step 2.
NO
Go to step 3.
2. Set BATT/EXT PWR switch to OFF. Check for
open between (A77)J4-C and CB29-1.
Does short exist?
YES
Repair open wire between
(A77)J4-C and CB13-1.
Go to paragraph 9304.
NO
Repair open wire between
P461-G and P769-C.
Go to paragraph 9304.
3. Set BATT/EXT PWR switch to OFF. Check for
short between P461-G and ground.
Does open exist?
YES
Go to step 4.
NO
Go to paragraph 923 to
troubleshoot dc electrical power
generation.
4. Check for short between (A77)J4-C and ground.
Does short exist?
YES
Go to step 5.
NO
Repair shorted wire between
P461-G and P769-C.
Go to paragraph 9304.
5. Detach wire at CB13-1. Check for short between
(A77)J4-C and ground.
Does short exist?
YES
Repair shorted wire between
(A77)J4-C and CB13-1.
Go to paragraph 9304.
NO
Replace bus bar between CB29
and CB13, and check for foreign
material (TM 1-1520-238-23).
END OF TASK