TM 1-1520-238-T-6
9619
9319. SHORT EXISTS BETWEEN (A77)J239 AND GROUND (cont)
9319
8. Check for short between CB22-1 and ground.
Does short exist?
YES
Replace MSL R INBD LCHR
DC circuit breaker (CB22)
(TM 1-1520-238-23).
NO
Go to step 9.
9. With CB22 wires attached, detach wires at
CB19-1. Check for short between (A77)J2-39
and ground.
Does short exist?
YES
Repair shorted wire between
CB22-1 and CB19-1.
Go to paragraph 9317.
NO
Replace MSL R OUTBD LCHR
DC circuit breaker (CB19)
(TM 1-1520-238-23).
END OF TASK