9323. CONTINUITY BETWEEN (A77): J2-39 AND J2-25 DOES NOT EXIST OR SHORT
9323
EXISTS BETWEEN J2-25 AND GROUND
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
Paragraph 9149
Pilot circuit breaker panel
accessing completed
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Check for open between (A77):
J2-39 and J2-25.
Does open exist?
YES
Go to step 2.
NO
Go to step 4.
2. Check for open between (A77)J2-39 and
CB22-1.
Does open exist?
YES
Repair open wire between
CB27-1 and CB22-1.
Go to paragraph 9317.
NO
Go to step 3.
3. Check for open between (A77)J2-25 and
CB22-2.
Does open exist?
YES
Repair open wire.
Go to paragraph 9317.
NO
Replace MSL R INBD LCHR
DC circuit breaker (CB22)
(TM 1-1520-238-23).
4. Detach wire at CB22-2. Check for short between
(A77)J2-25 and ground.
Does short exist?
YES
Repair shorted wire between
(A77)J2-25 and CB22-2.
Go to paragraph 9317.
NO
Replace MSL R INBD LCHR
DC circuit breaker (CB22)
(TM 1-1520-238-23).