9326. CIRCUIT BREAKER EDGE-LIGHT PANELS MAINTENANCE OPERATIONAL
9326
CHECK (cont)
M69-281
L CSL
CONTROL
Figure 9205.
Pilot EXT LT/INTR Panel
Task
Result
d. On CPG circuit breaker panel 1 (fig. 9206),
check that PRI LT circuit breaker (CB14) is
closed.
If PRI LT circuit breaker (CB14) does not stay closed,
go to paragraph 9132 to troubleshoot CPG
edge-lights.
M69-283
PRI LT
Figure 9206.
CPG Circuit Breaker Panel 1
e. On CPG INTR LT panel (fig. 9207), set L
CSL control to BRT. Check that both CPG
circuit breaker panel edge-light panels are
lighted.
If CPG circuit breaker panel 1 is not lighted, replace
panel lamps (TM 1-1520-238-23). If lamps still do not
light, go to paragraph 9329.
If CPG circuit breaker panel 2 is not lighted, replace
panel lamps (TM 1-1520-238-23). If lamps still do not
light, go to paragraph 9330.
f. On CPG INTR LT panel, set L CSL control
to OFF.