9364. CPG CAUTION AND WARNING SYSTEM MAINTENANCE OPERATIONAL CHECK
9364
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
References:
TM 1-1520-238-23
TM 9-1230-476-20-2
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
Equipment Conditions:
Ref
Condition
Paragraph 9132
CPG EDGE-LIGHT
MAINTENANCE
OPERATIONAL CHECK
completed
Paragraph 945
EXTERNAL POWER
POWER UP completed
WARNING
Turn off power before detaching or attaching wires and connectors. High
current 28 VDC or 115 VAC is present. Failure to do so could result in death
or serious injury.
NOTE
Refer to pilot station (fig. 9226) and CPG station (fig. 9227) for cockpit
configuration and equipment.
If referenced out of one paragraph or volume into another for additional
troubleshooting, upon completion of the task, return to the maintenance
operational check for the original paragraph or volume.