TM 1-1520-238-T-69–6939–364. CPG CAUTION AND WARNING SYSTEM – MAINTENANCE OPERATIONAL CHECK (cont)9–3641. PILOT FORWARD CIRCUIT BREAKER PANEL2. PILOT CAUTION / WARNING PANEL12M69-325Figure 9–226.Pilot Station1. CPG CIRCUIT BREAKER PANEL 12. CPG INTR LT PANEL3. CPG FIRE CONTROL PANEL4. CPG ARM / SAFE INDICATOR5. CPG ENG 1 / ENG 2 FIRE PULL INDICATORS6. CPG ORT7. CPG MASTER CAUTION / WARNING PANEL8. CPG CAUTION / WARNING PANEL12345678M69-326Figure 9–227.CPG Station1. Perform the maintenance operational check as follows:TaskResulta. On CPG circuit breaker panel 1 (fig. 9–228),check that EMERG BATT CAUT (CB29),FCFCC AC(CB16), FC FCC DC(CB4), MUXFAB R(CB9) and MUX CPG(CB15) circuitbreaker are closed.If EMERG BATT CAUT circuit breaker (CB29) doesnot stay closed, go to paragraph 9–366.If FC FCC AC (CB16),FC FCC DC (CB4),MUX FABR(CB9) and MUX CPG(CB15) circuit breakers donot stay closed, refer to TM 9-1230-476-20-2 totroubleshoot fire control system.b. On pilot forward circuit breaker panel(fig. 9–229), check that MISSION FC AC(CB51) andMISSION FC DC (CB50) circuitbreakers are closed.If MISSION FC AC (CB51) andMISSION FC DC(CB50) circuit breakers do not stay closed, refer toTM 9-1230-476-20-2 to troubleshoot fire controlsystem.