9364. CPG CAUTION AND WARNING SYSTEM MAINTENANCE OPERATIONAL CHECK (cont)
9364
1. PILOT FORWARD CIRCUIT BREAKER PANEL
2. PILOT CAUTION / WARNING PANEL
1
2
M69-325
Figure 9226.
Pilot Station
1. CPG CIRCUIT BREAKER PANEL 1
2. CPG INTR LT PANEL
3. CPG FIRE CONTROL PANEL
4. CPG ARM / SAFE INDICATOR
5. CPG ENG 1 / ENG 2 FIRE PULL INDICATORS
6. CPG ORT
7. CPG MASTER CAUTION / WARNING PANEL
8. CPG CAUTION / WARNING PANEL
1
2
3
4
5
6
7
8
M69-326
Figure 9227.
CPG Station
1. Perform the maintenance operational check as follows:
Task
Result
a. On CPG circuit breaker panel 1 (fig. 9228),
check that EMERG BATT CAUT (CB29), FC
FCC AC (CB16), FC FCC DC (CB4), MUX
FAB R (CB9) and MUX CPG (CB15) circuit
breaker are closed.
If EMERG BATT CAUT circuit breaker (CB29) does
not stay closed, go to paragraph 9366.
If FC FCC AC (CB16), FC FCC DC (CB4), MUX FAB
R (CB9) and MUX CPG (CB15) circuit breakers do
not stay closed, refer to TM 9-1230-476-20-2 to
troubleshoot fire control system.
b. On pilot forward circuit breaker panel
(fig. 9229), check that MISSION FC AC
(CB51) and MISSION FC DC (CB50) circuit
breakers are closed.
If MISSION FC AC (CB51) and MISSION FC DC
(CB50) circuit breakers do not stay closed, refer to
TM 9-1230-476-20-2 to troubleshoot fire control
system.