TM 1-1520-238-T-7
10234
1088. FWD CLOSED INDICATOR IS NOT LIGHTED WITH LVL CONT VALVES FWD
1088
TNK SWITCH SET TO CLOSE
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-T-4
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provision
R160 door open
TM 1-1520-238-T-4
Maintenance headset
connected
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. On refueling panel, set FUEL QTY switch to IND
ON and press FWD CLOSED indicator.
Is indicator lighted?
YES
Go to step 2.
NO
Go to step 8.
2. Apply 28 VDC at P2601, check for 28 VDC at
P2609.
Is voltage present?
YES
Replace refueling panel
(TM 1-1520-238-23).
NO
Go to step 3.
3. Check for open between (A58):
J110 and J111.
Does open exist?
YES
Go to step 4.
NO
Go to step 5.
4. Check for open between (A58):
J21 and J22.
Does open exist?
YES
Replace forward fuel cell fuel
level control pilot valve
(TM 1-1520-238-23).
NO
Replace forward fuel cell
fuel/defuel check valve
(TM 1-1520-238-23).
5. Apply 28 VDC at P2601 and check for 28 VDC
at P10661.
Is voltage present?
YES
Go to step 6.
NO
Go to step 7.
6. Check for open between:
P10663 and ground,
P10664 and P26310,
P26311 and ground,
P10662 and P440B19,
(A402)J16B19 and (A402)TB211E,
(A402)TB211F and (A402)J31A3,
P4443 and P2609.
Does open exist?
YES
Repair open wire.
Go to paragraph 1076.
NO
Replace forward fuel cell
isolation fuel valve switch
(TM 1-1520-238-23).