TM 1-1520-238-T-7
10236
1089. AFT CLOSED INDICATOR IS NOT LIGHTED WITH LVL CONT VALVES AFT
1089
TNK SWITCH SET TO CLOSE
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-T-4
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provision
R160 door open
TM 1-1520-238-T-4
Maintenance headset
connected
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. On refueling panel, set FUEL QTY switch to IND
ON and press AFT CLOSED indicator.
Is indicator lighted?
YES
Go to step 7.
NO
Go to step 2.
2. Apply 28 VDC at P2602 and check for 28 VDC
at P2608.
Is voltage present?
YES
Replace refueling panel
(TM 1-1520-238-23).
NO
Go to step 3.
3. Check for open between (A59):
J110 and J111.
Does open exist?
YES
Go to step 4.
NO
Go to step 5.
4. Check for open between (A59):
J21 and J22.
Does open exist?
YES
Replace aft fuel cell fuel level
control pilot valve
(TM 1-1520-238-23).
NO
Replace aft fuel cell fuel/defuel
check valve
(TM 1-1520-238-23).
5. Check for open between:
P2602 and P10671,
P2608 and P10672.
Does open exist?
YES
Repair open wire.
Go to paragraph 1076.
NO
Go to step 6.
6. Check for open between:
P10673 and ground,
P10674 and P26410,
P26411 and ground.
Does open exist?
YES
Repair open wire between:
P10673 and GS610B,
P10674 and P26410,
P26411 and GS610C.
Go to paragraph 1076.
NO
Replace aft fuel cell isolation
switch (TM 1-1520-238-23).
7. Check for 28 VDC at P2603.
Is voltage present?
YES
Replace refueling panel
(TM 1-1520-238-23).
NO
Go to paragraph 1078.
END OF TASK