TM 1-1520-238-T-7
10242
Change 1
1094. FUEL FILL CIRCUIT BREAKER DOES NOT STAY CLOSED WITH LVL CONT
1094
VALVES SWITCHES SET TO CLOSE (cont)
9. Check for short between P179B1 and ground.
Does short exist?
YES
Go to step 10.
NO
Go to step 11.
10. Detach P1066. Check for short between
P179B1 and ground.
Does short exist?
YES
Repair shorted wire between:
P179B1 and J914B17,
P914B17 and P10661.
Go to paragraph 1076.
NO
Replace forward fuel isolation
switch (TM 1-1520-238-23).
11. Detach P179. Attach positive meter lead to
P2601 and check for short to ground.
Does short exist?
YES
Go to step 12.
NO
Go to step 15.
12. Detach P440. Check for short between P2601
and ground.
Does short exist?
YES
Go to step 13.
NO
Go to step 14.
13. Detach P441 and P444. Check for short
between:
P179B2 and ground,
P2601 and ground.
Does short exist?
YES
Repair shorted wire between:
P179B2 and P441B18,
P2601 and P444A6.
Go to paragraph 1076.
NO
Repair shorted wire between
(A402):
J24B18 and TB211C,
J31A6 and TB211B,
J16B13 and TB211A.
Go to paragraph 1076.
14. Detach P942. Check for short between
P440B13 and ground.
Does short exist?
YES
Repair shorted wire between
P9421 and P440B13.
Go to paragraph 1076.
NO
Replace forward fuel cell fuel
level control pilot valve
(TM 1-1520-238-23).
15. Detach P440. Check for short between P2609
and ground.
Does short exist?
YES
Go to step 17.
NO
Go to step 16.
16. Detach P1066 and check for short between
P440B19 and ground.
Does short exist?
YES
Repair shorted wire between
P440B19 and P10662.
Go to paragraph 1076.
NO
Replace forward fuel isolation
switch (TM 1-1520-238-23).
17. Detach P429, P444 and P440. Check for short
between:
P179B3 and ground,
P2609 and ground.
Does short exist?
YES
Repair shorted wire between:
P179B3 and P429A20,
P2609 and P444A3.
Go to paragraph 1076.
NO
Repair shorted wire between
(A402):
J23A20 and TB211G,
J31A3 and TB211F,
J16B19 and TB211E.
Go to paragraph 1076.
END OF TASK