TM 1-1520-238-T-7
10247
1099. FUEL SYSTEM AIR PRESSURE IS NOT HEARD VENTING OVERBOARD
1099
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-T-4
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provision
R160 door open
TM 1-1520-238-T-4
Maintenance headset
connected
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. On refueling panel, with REFUEL VALVE switch
set to OPEN, check REFUEL VALVE OPEN
indicator.
Is indicator lighted?
YES
Go to step 2.
NO
Go to paragraph 1078.
2. Check for 28 VDC at P10861.
Is voltage present?
YES
Go to step 3.
NO
Go to step 4.
3. Check for open between P10862 and
GS360B.
Does open exist?
YES
Repair open wire.
Go to paragraph 1076.
NO
Replace fuel vent shutoff valve
(TM 1-1520-238-23).
4. Check for open between P10861 and P26016.
Does open exist?
YES
Repair open wire.
Go to paragraph 1076.
NO
Replace refueling panel
(TM 1-1520-238-23).
END OF TASK