1177. 26 VAC EXCITATION XFMR 2 NO-GO AFT AVIONICS BAY
1177
APPEARS ON HOD (cont)
17. (ACA) Check for short between P493A9 and
ground.
Does short exist?
YES
Repair shorted wire between
P493A9 and P2266.
Go to paragraph 1123.
NO
Go to step 19.
18. (ACB) Check for short between P6943 and
ground.
Does short exist?
YES
Repair shorted wire between:
P6943 and P445B3,
J445B3 and J2301.
Go to paragraph 1123.
NO
Go to step 20.
19. (ACA) Check for short between P493A11 and
ground.
Does short exist?
YES
Repair shorted wire between
P493A11 and J225a.
NO
Go to step 21.
20. (ACB) Check for short between P6945 and
ground.
Does short exist?
YES
Repair shorted wire between:
P6945 and P445B6,
J445B6 and P413A15,
P472B5 and J2321.
(A326):
J10A15 and J15B5.
Go to paragraph 1123.
NO
Go to step 22.
21. (ACA) Check for short between wire end
(A323)TB37M and ground.
Does short exist?
YES
Repair shorted wire between:
P402B13 and J75613,
P499A16 and J402B13,
P75613 and J2231.
(A323):
J5A16 and TB37M.
Go to paragraph 1123.
NO
Go to step 23.
22. (ACB) Check for short between P6947 and
ground.
Does short exist?
YES
Repair shorted wire between:
P6947 and P445B8,
J445B8 and P413A5,
P472B15 and J2311.
(A326):
J10A5 and J15B15.
Go to paragraph 1123.
NO
Go to step 24.
23. (ACA) Check for short between wire and
(A323)TB37L and ground.
Does short exist?
YES
Repair shorted wire between:
P499A18 and J402A5,
P402A5 and J7565,
P7565 and P2246.
(A323):
J5A18 and TB37L.
Go to paragraph 1123.
NO
Go to step 25.
24. (ACB) Check for short between P69423 and
ground.
Is voltage present?
YES
Repair shorted wire between:
P69423 and J402A5,
P402A5 and J7565,
P7565 and P2246.
Go to paragraph 1123.
NO
Go to step 26.