TM 1-1520-238-T-7
11317
1178.
LONG ACTUATOR NO-GO APPEARS ON HOD
1178
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
R295 door open
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Check for 1800 to 2200 ohms between P68849
and P68850.
Is resistance present?
YES
Go to step 3.
NO
Go to step 2.
2. Check for open between:
P2204 and P68849,
P2205 and P68850.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Replace longitudinal
servocylinder
(TM 1-1520-238-23).
3. Check for 90 to 100 ohms between:
(ACA) P683109 and P493B9.
(ACB) P683109 and ground.
Is resistance present?
YES
Go to step 5.
NO
Go to step 4.
4. Check for open between:
P683109 and P2202.
(ACA) P493B9 and P2209.
(ACB) P2209 and ground.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Replace longitudinal
servocylinder
(TM 1-1520-238-23).
5. Check for 90 to 100 ohms between P683101
and P683102.
Is resistance present?
YES
Go to step 7.
NO
Go to step 6.
6. Check for open between:
P683101 and P22011,
P683102 and P22010.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Replace longitudinal
servocylinder
(TM 1-1520-238-23).
7. Check for 364 to 424 ohms between P68823
and P68824.
Is resistance present?
YES
Go to step 9.
NO
Go to step 8.