TM 1-1520-238-T-7
Change 5
11345
1188.
STABILATOR MAINTENANCE OPERATIONAL CHECK (cont)
1188
Task
Result
To prevent damage to stabilator during movement, be sure stabilator is
clear of all obstructions before proceeding.
CAUTION
h. On pilot aft circuit breaker panel
(fig. 11125), open STAB MAN AC, STAB
MAN DC, STAB AUTO AC, and STAB
AUTO DC circuit breakers. Close the circuit
breakers in the following order:
(1) STAB MAN AC
(2) STAB MAN DC (Briefly toggle PLT
NU/ND between NU and ND)
If STAB MAN AC circuit breaker does not stay
closed, go to paragraph 1190.
If STAB MAN DC circuit breaker does not stay
closed, go to paragraph 1191.
If caution/warning panel MAN STAB indicators (fig.
11122) are not lighted, go to paragraph 11119.
M70-194
STAB AUTO AC
STAB
MAN AC
STAB
MAN DC
STAB AUTO DC
Figure 11125.
Pilot Aft Circuit Breaker Panel