TM 55-6930-214-10
7-27. CURRENT CONDITIONS. Current conditions pages 150 and 151 are lists of the
current parameters and conditions of the simulated aircraft at any given time while
it is being used for training. Parameters being shown are identical to the initial
conditions (IC) set while the stimulator is in freeze following initialization.
When out of freeze, the current conditions pages reflect the actual state of the
simulator.
The status of each of the items/parameters is shown on the currant condi-
tions CRT pages (figure 7-12). Items or parameters with line reference numbers can
be modified during training. Host items/parameters can be changed while out of
freeze. but to change others, the simulator must be in a freeze state to preclude
discontinuities.
The current conditions pages contain the following categories:
Aircraft
Tactics
Miscellaneous
Visual
Environmental
Doppler navigation
Lighting
Waypoint/targeting
b. The first four categories cm page 150 are essentially the same on the current
conditions page as in the IC sets.
The current conditions page located in group 1 (IC/CC) can be accessed via
the data entry keyboard by keying in 150 DISPL. (Ranges of values for each
parameter/item are listed In table 7-6.) To modify the following items/parameters,
the simulator must be In a freeze state:
Line
01/02
Altitude
Line
04
Heading
Weapons load
Line
06
Line
08
10 meter resolution
Present position
Line
09
1 meter resolution
Present position
NOTE
Random visibility (line 28) is available only if the visibility
(line 23) is 2000 feet or below.
NOTE
To change items/parameters when operating in the independent
mode, refer to missing man operating paragraph 7-57 and missing
man/independent mode display CRT page 175.
d. Two categories of Information/control included on the current conditions
page, but not on the initial conditions page, art tactics and miscellaneous.
e. Any set of current conditions can be saved temporarily by depressing STORE on
the IOS forward control panel. This data is then available for recall and
relocation by depressing PROB FREEZE and RESET. If the instructor desires to save
more than one set of current conditions during a period. they can be saved by
designating the sets as a temporary IC set. Up to 45 IC sets can be temporarily
saved. To save a temporary IC set from current conditions, perform the following
procedures:
7-42
Change 2