Table 7-16.
Malfunction Details - Continued
Indications presented
Required
Ref
Aircraft indications
Corrective
to instructor/operator
malfunction
number
and related effects
action
and trainee
MSL L
23014
CPG main CB panel.
Noncorrectable
Instructor: MSL L INBD AC
INBD AC
appears on CRT.
Trainee: Circuit breaker
pops. Loss of ac power to
left inboard launcher. Un-
able to fire left-hand in-
board missiles.
MSL R
23015
CPG main CB panel.
Noncorrectable
Instructor : MSL R INBD DC
INBD DC
appears on CRT.
Trainee: Circuit breaker
pops. Loss of dc power to
right inboard launcher. Un-
able to fire right-hand in-
board missiles.
MSL L
23016
CPG main CB panel.
Noncorrectable
Instructor: MSL L OUTBD AC
OUTBD AC
appears on CRT.
Trainee : Circuit breaker
pops. Loss of ac power to
left outboard launcher.
Unable to fire left-hand
outboard missiles.
FC FCC
23017
CPG main CB panel.
Noncorrectable
Instructor: FC FCC AC
AC
appears on CRT.
Trainee: Circuit breaker
pops. Loss of ac power to
FCC. No FCC functions
available.