Table 7-16.
Malfunction Details - Continued
Indications presented
Required
Ref
Aircraft indications
Corrective
to instructor/operator
malfunction
number
action
and related effects
and trainee
FC FCC
23018
CPG main CB panel.
Noncorrectable
Instructor: FC FCC DC
DC
appears cm CRT.
Trainee: Circuit breaker
pops. Loss of dc power to
FCC. FCC switches to second-
dary. If MIX switch is in
primary position, PRI MUX
caution light illuminates.
FC RCDR
23019
CPG main CB panel.
Noncorrectable
Instructor:
FC RCDR appears
on CRT.
Trainee: Circuit breaker
-
-
pops. Loss of power to
recorder panel.
ATTD IND
23020
CPG main CB panel.
Noncorrectable
Instructor:
ATTD appears on
CRT.
Trainee: Circuit breaker
pops. Loss of power to CPG.
ADI, and RMI systems. A l l
indications on both instru-
ments freeze at current con-
ditions, with flags in view.