Correction Procedures - Continued
Correction Procedures - Continued

Antenna Cables, Ah-1F, Ah-64A/D, Ch-47D/E, Oh-58A/C/D, And Uh-60A/L/Q/Eh-60A Helicopters Page Navigation
  1    2    3    4  5  6    7    8    9    10  
img
TB 1-1500-351-20-1
Location
FWD LEFT
AFT LEFT
FWD RIGHT
AFT RIGHT
Straight Connector
28 inches
29 inches
36 inches
36 inches
M17/128-RG-400
RG-400 Cable
3
3
3
3
MIL-I-23053/4 White
Sleeve Marker
2
2
2
2
M23053/5-106-0
Shrink Tubing
SD18573, 45 degree connectors can be used to prevent chafing of the cables in all locations.
UH-60A/L/Q/EH-60A
Location
FWD LEFT
AFT LEFT
FWD RIGHT
AFT RIGHT
New Part Number
5595-CAB39-001-9
5595-CAB39-
5595-CAB39-001-11
5595-CAB39-001-12
001-10
70600-00204-041
70600-00204-042
70600-00204-061
70600-00204-062
Old Part Number
1
1
1
1
SD18573 45 degree
Connector
1
1
1
1
SD18574 Straight
Connector
SD18575 90 degree
Connector
31 inches
31 inches
38 inches
38 inches
M17/128-RG-400
RG-400 Cable
3
3
3
3
MIL-I-23053/4 White
Sleeve Marker
2
2
2
2
M23053/5-106-0
Shrink Tubing
SD18573, 45 degree connectors can be used to prevent chafing of the cables In ail locations.
a.
Cable Assembly Instructions:
1.
Cut the RG-400/U, cable material to the length that is required for the appropriate aircraft located in
the aircraft table.