TM 1-1520-238-10
Change 10
5-3
RED
RED
RED
YELLOW
YELLOW
YELLOW
GREEN
GREEN
BLUE
949
MAXIMUM
903 949 TRANSIENT (12 SECONDS)
878 903 SINGLE ENGINE CONTINGENCY (2.5 MINUTE LIMIT)
851
MAXIMUM DURING START
851 878 MRP (10 MINUTES)
810 851 IRP (30 MINUTES)
810
MCP
0 810
NORMAL OPERATION
INSTRUMENT POWER ON
RED
RED
RED
YELLOW
YELLOW
GREEN
GREEN
BLUE
965
MAXIMUM
917 965 TRANSIENT (12 SECONDS)
867 917 SINGLE ENGINE CONTINGENCY (2.5 MINUTE LIMIT)
867
MAXIMUM DURING START
807 867 IRP (30 MINUTES)
807
MCP
0 807
NORMAL OPERATION
INSTRUMENT POWER ON
ENGINE TURBINE GAS TEMPERATURE (TGT _C)
M011311B
NOTE:
LIMITS BASED ON INDICATED TGT
LEGEND
RED
YELLOW
GREEN
BLUE
CAUTION
Each engine incoroporates a steady state TGT limiter control which
limits engine operation according to the follwing indicated TGT values;
Dual Engine:
860_ ) / 9_C (851 869_C)
Single Engine:
917_ ) / 9_C (908 926_C)
The limit value within these ranges can change over a period of time.
Each engine incoroporates a steady state TGT limiter control which
limits engine operation according to the follwing indicated TGT values;
Dual Engine:
866_ ) / 9_C (857 875_C)
The limit value within these ranges can change over a period of time.
Single Engine:
896_ ) / 9_C (887 905_C)
ENGINE TURBINE GAS TEMPERATURE (TGT _C)
CAUTION
LIMITS
LIMITS
Figure 5-1.
Instrument Markings (Sheet 1 of 5)