TM 1-1520-238-10
5-4
Change 9
RED
YELLOW
GREEN
RED
BLUE
RED
YELLOW
(UPPER) 102 105 TRANSIENT 12 SECOND MAXIMUM
99 102
30 MINUTE LIMIT
63 99
NORMAL OPERATION
(LOWER) 63
MINIMUMENGINE OUT WARNING LIGHT
SET AT THIS VALUE
INSTRUMENT POWER ON
BEGINNING OF A RED RANGE (FROM A NORMAL
OPERATING REFERENCE)
BEGINNING OF A YELLOW RANGE (FROM A
NORMAL
OPERATING RANGE)
LIMITS
TORQUE (%)
M011312A
C
S
C
S
LEGEND
RED
YELLOW
GREEN
BLUE
ENGINE GAS GENERATOR SPEED (N
G
) (RPM%)
RED
RED
WHITE
RED
WHITE
GREEN
YELLOW
YELLOW
BLUE
BEGINNING OF RED RANGE (FROM A NORMAL OPERATING
REFERENCE)
122 125 SINGLE ENGINE TRANSIENT (6 SECOND LIMIT)
122
SINGLE ENGINE CONTINGENCY POWER (2.5 MINUTE LIMIT)
100 115 DUAL ENGINE TRANSIENT (6 SECOND LIMIT)
110
SINGLE ENGINE MAXIMUM CONTINUOUS POWER
0 100
DUAL ENGINE NORMAL OPERATION
70
DO NOT EXCEED WITH LESS THAN 90% N
R
30
DO NOT EXCEED WITH LESS THAN 50% N
R
INSTRUMENT POWER ON
C
S
LIMITS
Figure 5-1.