TM 1-1520-238-23
1-46
1.18.
FUEL SERVICING HOT RAPID SINGLE POINT ADAPTER (SPA) METHOD continued
NOTE
FWD CLOSED and AFT CLOSED indi-
cators will light when fuel cell is full and
automatic shutoff has occurred.
m. Disconnect nozzle (4) from adapter (5).
(1) Stop refueling pump.
(2) Move valve handle (9) at OFF.
(3) Turn nozzle (4) counterclockwise until free
from adapter (5).
(4) Disconnect plug (6) from receptacle (7).
(5) Install cap (8) on adapter (5).
NOTE
Refueling panel door will not close if ei-
ther or both LEVEL CONT VALVES
switches are in CLOSE.
n. Move FWD TNK and AFT TNK LEVEL CONT
VALVES switches (10) to OPEN.
(1) Check that indicators FWD CLOSED and
AFT CLOSED (11) are not lighted.
NOTE
Notify pilot if indicators remain lighted.
o. Set REFUEL VALVE switch (2) to CLOSE.
(1) Check that OPEN indicator (3) is not lighted.
(2) Refer to TM 1-1520-238-T if indicator (3) re-
mains lighted.
p. Move FUEL QTY IND switch (1) to OFF.
GO TO NEXT PAGE
M04-2301-6
9
6
4
8
5
7
5
8
M04-2301-7
11
10
1
3
2