TM 1-1520-238-231-501.19.DEFUELING – SINGLE POINT ADAPTER (SPA) METHOD – continuede. Connect single point adapter nozzle (7) toadapter (8).(1) Connect nozzle ground plug (9) to groundingreceptacle (10).(2) Remove cap (11) from adapter (8).(3) Connect nozzle (7) to adapter (8). Turnnozzle clockwise until it locks.(4) Move handle (12) to ON.f. Start pressure defueling.CAUTIONFuel system may be damaged if air doesnot flow into fuel cells during defueling.Stop defueling if no air flows into cells.g. Check vent tubes (13) and (14) for air flowinginto fuel cells.h. Stop pressure defueling.(1) Stop defueling when AFT and FWDFUELQTYindicator (15) indicates empty.GO TO NEXT PAGEM04-1594-57128129710911810M04-1594-11141315M04-1594-6