TM 1-1520-238-23
1-79
1.26.
APU OIL SYSTEM DRAINING AND SERVICING continued
a. Remove panel (1).
(1) Separate hook and pile fasteners (2).
(2) Remove four screws (3) and washers (4).
b. Remove chip collector (5) from magnetic
drain plug (6).
(1) Place rags under plug (6) to catch spills.
(2) Push and turn collector (5) counterclockwise
to remove.
(3) Remove and discard packing (7).
GO TO NEXT PAGE
3
M04-1602-2
4
2
2
1
M04-1602-3
5
7
6