TM 1-1520-238-23
1-105
1.34.
HYDRAULIC SYSTEMS SERVICING FLUID continued
f. Charge hydraulic accumulator to 3000 psi.
(1) Position pump selector lever (11) to accumu-
lator position aft.
(2) Fill accumulator until pressure gage (17) on
utility service panel (18) indicates 3000 psi.
UTIL ACC indicator on pilot instrument panel
may be used also. Use fluid service unit.
g. Return pump handle (6) to storage clip (9).
(1) Slide handle (6) off bellcrank (7).
(2) Place handle (6) in clip (9).
(3) Install retaining pin (8) through clip (9).
h. Remove hose (1) and adapter (5) from union
(2).
(1) Hold union (2). Remove adapter (5).
(2) Install dust cap (4) on union (2).
i. Remove external power air (para 1.71).
j. Remove external power hydraulic (primary
or utility) (para 1.72 or 1.73).
k. Secure access doors L190 and R325 (para
2.2).
END OF TASK