TM 1-1520-238-23Change 51-114.31.35.HYDRAULIC SYSTEM BLEED – continued(c) Slowly push pilot right pedal (46) forwardto stop then back to center. Repeat for leftpedal. Repeat 10 complete cycles.(3) Verify primary and utility manifold fluid levelsare correct (para 1.34).(4) Check for air bubbles in the AGPU air bleedsight gage. Repeat steps (1) and (2) as re-quired to clear remaining bubbles.ac Reduce AGPU output pressure to 0 psi andshut down AGPU (TM 55-1730-229-12).ad Disconnect AGPU return hose (13) from re-turn “Y” hose coupling (14).(1) Turn coupling nut (16) counterclockwise untilit clears “Y” hosecoupling (14).(2) Install cap (15) on “Y” hose coupling (14).ae Disconnect AGPU pressure hose (17) frompressure “Y” hose coupling (18).(1) Turn coupling nut (20) counterclockwise untilit clears “Y” hose coupling (18).(2) Install cap (19) on “Y” hose coupling (18).af Perform APU power up (para 1.75).ag Perform TADS power up(TM 1-1270-476-20).ah Perform area weapon system power up(TM 9-1090-208-23).WARNINGHydraulic pressure is 3000 psi. Thiscan cause injury. If injury occurs,seek medical aid.To prevent injury when moving gunturret, ensure that all personnel areclear of gun travel area during turretoperation. If injury occurs, seekmedical aid.GO TO NEXT PAGEPILOT STATIONM04-1611-32461513172016181419M04-1611-33