TM 1-1520-238-23
Change 5
1-114.5
1.35.
HYDRAULIC SYSTEM BLEED continued
ak. Repeat step ab.(1) and (2) to articulate pylons
and flight controls 10 complete cycles.
al. Perform area weapon system power down
(TM 9-1090-208-23).
am. Perform APU power down (para 1.75).
an. Connect AGPU return hose (13) to return Y
hose coupling (14).
(1) Remove cap (15) from Y hose coupling
(14).
(2) Turn coupling nut (16) clockwise until seated
and locking teeth engage fully with teeth on
Y hose coupling (14).
ao. Connect AGPU pressure hose (17) to pres-
sure Y hose coupling (18).
(1) Remove cap (19) from Y hose coupling
(18).
(2) Turn coupling nut (20) clockwise until seated
and locking teeth engage fully with teeth on
Y hose coupling (18).
CAUTION
Hydraulic pressure is 3000 psi. This can
cause injury. If injury occurs, seek medi-
cal aid.
ap. Apply hydraulic pressure to helicopter.
(1) Adjust AGPU output pressure to 3000 psi
(TM 55-1730-229-12).
aq. Turn AGPU low pressure bleed valve 1/4 turn
open
(CCW)
for
system
bleed
(TM 55-1730-229-12).
GO TO NEXT PAGE
M04-1611-37
15
13
17
20
16
18
14
19