TM 1-1520-238-23
1-114.4
Change 5
1.35.
HYDRAULIC SYSTEM BLEED continued
NOTE
Gun will be slaved to TADS to accomplish
azimuth and elevation movement.
ai. Actuate area weapons system.
(1) Cycle gun 10 complete cycles in azimuth and
elevation.
(a) Set switches on CPG FIRE CONTROL
panel (25):
Switch
Position
PLT/GND (26)
ORIDE
CPG SAFE/ARM (27)
SAFE
GUN (28)
NORM
(b) Set RKT/GUN/MSL switch (23) on CPG
ORT left handgrip (24) to GUN.
(2) Select N/Z/W/M field of view switch (47) on
CPG ORT left handgrip (24) to M medium
field of view position.
(3) Slew TADS to full up elevation, then to full
down elevation (TM 1-1270-476-20). Repeat
10 complete cycles.
(4) Slew TADS to full left azimuth, then to full
right azimuth (TM 1-1270-476-20). Repeat
10 complete cycles.
(5) Set RKT/GUN/MSL switch (23) on CPG ORT
left handgrip (24) to center position.
(6) Set GUN NORM/OFF/FIXED switch (28) on
CPG FIRE control panel (25) to OFF.
aj. Perform
TADS
power
down
(TM 1-1270-476-20).
GO TO NEXT PAGE
M04-1611-38
26
25
28
27
25
23
24
M04-1611-35
47