TM 1-1520-238-23
1-117
1.36.
UTILITY HYDRAULIC ACCUMULATOR SERVICING NITROGEN continued
WARNING
The utility hydraulic accumulator con-
tains high pressure nitrogen. Open
and close valve carefully to prevent
possible injury from sudden blast. If
injury occurs, seek medical aid.
i. Vent utility hydraulic pressure (para 7.57).
j. Connect nitrogen truck service hose (7) to
valve (8).
(1) Remove cap (9) from valve (8).
(2) Hold valve (8). Loosen nut (10). Do not allow
pressure to escape.
(3) Install service hose nut (11) on valve (8).
k. Service utility hydraulic accumulator accord-
ing to specifications on chart (12).
(1) Loosen nut (10) until resistance is felt; then
loosen 1/2 to 3/4 turn to off seat valve.
(2) Select correct pressure from chart (12) ac-
cording to temperature.
(3) Tighten nut (10) when gage (13) reads cor-
rect pressure.
NOTE
Allow pressure to stabilize 5 minutes. Ad-
just pressure if necessary.
GO TO NEXT PAGE
11
13
9
10
8
M04-1621-1
8
13
7
+105 TO +115
+115 TO +125
+125 TO +135
+135 TO +145
+95 TO +105
+85 TO +95
+75 TO +85
M04-1621-3
1775-1825
1805-1855
1745-1795
1625-1675
1715-1765
1685-1735
1595-1645
1655-1705
1565-1615
1505-1555
1535-1585
1474-1525
1415-1465
1445-1495
1385-1435
-45 TO -35
1355-1405
-55 TO -45
-35 TO -25
-65 TO -55
1325-1375
1835-1885
1295-1345
1265-1315
1235-1285
-25 TO -15
-15 TO -5
-5 TO +5
+5 TO +15
+15 TO +25
+25 TO +35
+35 TO +45
+45 TO +55
+55 TO +65
+65 TO +75
13
12
OUTSIDE
AIR
TEMPERATURE
(ºF)
NITROGEN
PRESSURE
(psig)