TM 1-1520-238-23
1-116
1.36.
UTILITY HYDRAULIC ACCUMULATOR SERVICING NITROGEN continued
d. Set EMER HYD switch (3) on EMER HYD panel
(4) to EMER HYD.
e. Move pilot cyclic stick (5) until UTIL ACC indi-
cator (6) indicates 0 psi.
f. Set EMER HYD switch (3) on EMER HYD panel
(4) to OFF.
g. Set BATT/EXT PWR switch (1) on ELEC PWR
control panel (2) to OFF.
h. Disconnect battery (para 9.40).
GO TO NEXT PAGE
4
3
M04-1621-6
M04-1621-7
5
PILOT STATION
4
3
6
M04-1621-8
M04-1621-9
1
2