TM 1-1520-238-23
1-299
1.97.
MAINTENANCE CRANE INSTALLATION continued
c. Set pilot ELEC PWR panel (1) BATT EXT PWR
switch (2) to BATT.
d. Set pilots power lever quadrant (3) RTR BRK
switch (4) to OFF.
e. Set BATT EXT PWR switch (2) to OFF.
f. Disconnect battery plug (5) from battery re-
ceptacle (6).
NOTE
Pilot and CPG access doors must be
closed for crane installation on right side.
g. Aline two rotor blades (7) with longitudinal
centerline of helicopter.
GO TO NEXT PAGE
3
4
1
2
M04-1655-1
M04-1655-2
5
6
M04-1655-3
7
7