TM 1-1520-238-23
2-116
2.40.
CANOPY JETTISON ACCESS DOOR SEAL REPLACEMENT continued
b. Install new seal (6) on door (1).
(1) Apply a coat of cement to surfaces of door (1)
and seal (6). Use estane cement (item 79,
App F), estane cement accelerator (item 80,
App F), and brush (item 34, App F).
(2) Apply a coat of MIBK over cement to make
surfaces tacky. Use methyl isobutyl ketone
(item 125, App F) and cloth (item 52, App F).
(3) Carefully mate surfaces of seal (6) and door
(1).
(a) Start at one edge and work across bond-
ing area. Apply pressure to avoid forma-
tion of bubbles. Use hand roller.
(4) Clean excess cement from door (1). Use
cloth (item 52, App F) moistened with
naphtha (item 127, App F).
c. Inspect (QA).
2.40.6. Installation
a. Install door (1) on airframe (2).
(1) Install pin (4) in hinge halves (5)
(TM 1-1500-204-23).
(2) Secure latch (3) on door (1).
b. Inspect (QA).
END OF TASK
M04-4533-5
1
6
M04-4533-4
1
3
2
4
5