TM 1-1520-238-23
2-113
2.39.
CPG BORESIGHT MOUNT FITTING REMOVAL/INSTALLATION continued
2.39.5. Inspection
a. Check mount fitting and support fitting for
cracks and corrosion (para 2.11).
2.39.6. Installation
a. Install mount fitting (1) on support fitting (2).
(1) Aline three laminated washers (5) and mount
fitting (1) with support fitting (2).
(2) Install three bolts (3) and washers (4).
b. Inspect (QA).
c. Install CPG boresight reticle unit (BRU)
(TM 9-1270-221-23).
END OF TASK
2
3
4
1
5
M04-3373-3