TM 1-1520-238-23
2-165
2.56.
CPG STATION ACCESS DOOR MECHANISM REPAIR (AVIM) continued
m. Remove bar (50) from door (2).
(1) Install retention tool on bar mechanism (54).
(2) Hold clevis bolt (55). Remove self-locking cap
nut (56), washer (57), and sleeve bushing
(58) from bar mechanism (54).
(3) Remove bolt (55) and sleeve bushing (59)
from bar mechanism (54).
(4) Hold bolt (60). Remove self-locking cap nut
(61).
(5) Remove bolt (60), two washers (62), sleeve
bushing (63), two sleeve bushings (64), and
four washers (65).
(6) Remove bar (50) from door (2).
n. Remove aft locking bar mechanism (54) from
locking bar (66).
(1) Remove retainer (67), washer (68), helical
spring (69), and spring keeper (70) from bar
mechanism (54). Use retention tool.
(2) Remove bar mechanism (54) from bar (66).
o. Remove cable (21) from cable end adapter
(71).
(1) Remove and discard cotter pin (72).
(2) Remove cable (21) from adapter (71).
GO TO NEXT PAGE
M04-1441-12
60
62
646550
64
63
6261
58
5756
54
50
59
55
2
65
2
RETENTION TOOL
RETENTION TOOL
M04-1441-13
67
68
69
70
66
54
M04-1441-14
72
71
21
VIEW ROTATED