TM 1-1520-238-23
2-168
2.56.
CPG STATION ACCESS DOOR MECHANISM REPAIR (AVIM) continued
d. Install cable (21) on adapter (71).
(1) Install cable (21) on adapter (71).
(2) Install new pin (72) through adapter (71).
(3) Attach lockwire to loose end of cable (21) to
aid in installation. Use wire (item 228, App F).
e. Install bar mechanism (54) on bar (66).
(1) Stack and hold keeper (70), spring (69),
washer (68), and retainer (67) on bar (66).
Use retention tool.
GO TO NEXT PAGE
VIEW
ROTATED
21
71
72
21
M04-1441-22
70
69
68
67
66
54
RETENTION TOOL
M04-1441-23