TM 1-1520-238-23
2-170
2.56.
CPG STATION ACCESS DOOR MECHANISM REPAIR (AVIM) continued
h. Install link (77) on bar (78).
(1) Turn link (77) counterclockwise to lengthen or
clockwise to shorten until link (77) is 0.031
INCH from stop. Use gap setting gage.
(2) Install link (49) in guide (86).
(3) Aline link (77) with bar (78).
(4) Install pin (80) and washer (81).
(5) Install new cotter pin (79).
i. Install pulley (44) in door (2).
(1) Feed cable (21) through door (2) to upper
area and out bracket (32).
(2) Stack bushing (48), washer (47), pulley (44),
washer (47), and bushing (48) on 1/4 inch
dowel (91). Use dowel.
(3) Install cable (21) on pulley (44) and in door
(2).
(4) Insert pin (46) pushing 1/4 inch dowel (91)
through.
(5) Install washer (47) on pin (46).
(6) Install new cotter pin (45).
GO TO NEXT PAGE
78
77
49
0.031
86
M04-1441-27
79
81
77
80
78
M04-1441-28
2
45
91
44
47
44
46
21
32
48
47
21
48
47
M04-1441-29